Skip to main content
Fuse Boxes & Circuits

EV Charger Tripping the Electrics: Supply Limits, RCDs and Faulty Installs

By Emergency Electrician Bath · Published · Updated

Bath stone Georgian terrace in darkness during a power cut

A home EV charger is one of the largest loads most households will ever add. If it trips the RCD, cuts out mid-charge or blows the main fuse when the oven is on, the cause is usually the supply, the protection or the earthing rather than the car. This guide explains why chargers trip, what older Bath homes need to handle them, and how load management, the correct RCD and a proper earthing arrangement solve the problem.

How Much Power a Charger Draws

A typical 7 kW home charger draws around 32 amps continuously for hours at a time. That is more than an electric shower, and it runs much longer. Many older homes have a 60 or 80 amp main fuse. Add a charger to a house where the oven, kettle, tumble dryer and electric shower might all be used in the evening, and the total demand can exceed what the supply was designed for.

Load Typical current
7 kW EV charger 32 A for several hours
Electric shower (9.5 kW) 40 A for 10 minutes
Electric oven and hob in use 15 to 30 A
Kettle 13 A
Tumble dryer 10 to 13 A
Background household load 2 to 5 A

The Main Reasons Chargers Trip

1. The wrong RCD type

EV chargers can produce DC leakage currents. A standard Type AC RCD can be "blinded" by DC leakage and fail to work properly. Chargers need either a Type B RCD or a Type A RCD with built-in DC fault detection in the charger itself. If the protection is wrong, nuisance tripping or, worse, ineffective protection can result.

2. Shared RCD with other circuits

If the charger shares an RCD with other circuits, small leakage currents from several appliances can add up and trip it. Chargers should normally have their own dedicated circuit and protection.

3. Overloaded supply

If the total demand exceeds the main fuse rating, the main fuse can fail. That is a job for the network operator, who will need to replace it. Load management avoids this.

4. Earthing problems

Many homes use a PME (TN-C-S) earthing arrangement. Special rules apply to EV charging outdoors on PME supplies, because of the risk of a broken neutral making the car's body live. Chargers now usually include protection against this, but older installations or poorly installed chargers may not.

5. Water and damage

Outdoor charger units, cables and connectors can let water in, especially if mounted facing the weather. A damaged charging cable should not be used.

Load Management

Most modern chargers can be fitted with a current clamp on the incoming supply. When the house is using a lot of power, the charger slows down automatically, so the total demand stays within the supply limit. This is often the simplest way to fit a charger to a home with a 60 or 80 amp fuse without upgrading the supply.

Is Your Supply Big Enough?

Before a charger is installed, the installer should check the main fuse size, the condition of the meter tails and the earthing arrangement, and tell the network operator about the installation. In some cases, the network operator will upgrade the main fuse or the service cable. In older Bath streets, supplies can be shared between houses ("looped"), which may need separating.

What to Check If Your Charger Trips

  1. Note when it trips: at the start of charging, part way through, or when other appliances are switched on.
  2. Check whether it trips the RCD in the consumer unit, the charger's own internal protection, or the main fuse.
  3. Check the charger app or display for error codes.
  4. Look at the cable and connector for damage or water.
  5. Try charging with other large appliances switched off.

If it trips the main RCD, or the main fuse fails, call an electrician. Do not keep resetting. See is it safe to keep resetting a tripped breaker?

Installation Rules

EV charger installation is notifiable under Part P in most cases, and must follow BS 7671 and the IET Code of Practice for EV charging. The installer should provide an Electrical Installation Certificate and notify building control. Chargers installed with government grants must meet extra requirements, including smart functionality. See Part P building regulations explained.

Flats, Terraces and On-Street Parking

Many Bath homes have no off-street parking. Running a cable across a pavement to charge a car is not allowed without permission and creates a trip hazard. If you live in a flat or terrace, talk to the council about on-street charging options.

Frequently Asked Questions

Why does my EV charger trip the RCD?

Usually because the RCD is the wrong type, the charger shares an RCD with other circuits, or there is water or damage. Testing confirms which.

Can I charge my car from a normal socket?

Occasional use with a manufacturer's granny lead is possible, but a socket is not designed for long periods at high load. A dedicated charger is safer.

Do I need a new consumer unit for a charger?

Not always. Many chargers are fed from a separate small enclosure with their own protection. Your installer should check the existing board.

Will the charger overload my house?

Not if load management is fitted and the supply has been checked.

EV Charger Tripping the Power?

We test supplies, protection and earthing in Bath homes. See our fault finding service or call us.

Related Electrical Guides

Fast Call-Out

Get an Emergency Electrician
Out in Bath

Call 07893 943507 and tell us what has happened: what has tripped or stopped working, whether you can smell burning, and whether water is involved. An electrician from Emergency Electrician Bath comes to your Bath property, makes it safe, finds the fault and agrees the price with you before any repair starts.

Available now Open 24 hours
✓ Fast Call-Out ✓ BS 7671 Testing ✓ Written Quotes ✓ Based in Bath