Electric Underfloor Heating Not Working: Signs, Causes and What Can Be Saved

By Emergency Electrician Bath · Published · Updated

Water running down a hallway wall past a light switch

Electric underfloor heating is popular in bathrooms, kitchens and extensions in Bath homes, and when it works it is comfortable and invisible. When it stops working or starts tripping the RCD, the fault could be in the thermostat, the floor sensor, the connections or the heating cable itself, buried under tiles. This guide explains how to narrow it down, how electricians find a break without lifting the whole floor and when a mat can be repaired.

How Electric Underfloor Heating Works

A heating mat or loose cable is laid under the floor finish, usually tiles, stone or engineered wood. It is connected to a thermostat, normally on the wall, which reads a floor sensor (a probe laid between the heating cables) and sometimes an air sensor. The circuit is fed from the consumer unit through RCD protection, often via a fused spur.

Faults happen in three places: the controls (thermostat and sensor), the connections (at the thermostat and the "cold tail" joint where the supply cable meets the heating cable), and the heating cable itself.

Common Symptoms

Symptom Likely cause
Floor not warming, thermostat display normal Heating cable break, failed cold tail joint
Thermostat display blank No supply, tripped breaker, failed thermostat
Thermostat shows sensor error Failed or damaged floor sensor
Heating trips the RCD Damaged heating cable leaking to earth, water in connections
Warm in patches only Partial damage, some mats on separate circuits
Floor overheating Sensor failure, thermostat set wrong

Checks You Can Do

  1. Check the consumer unit for a tripped RCD or breaker.
  2. Check any fused spur for a blown fuse or switch turned off.
  3. Check the thermostat settings, schedule and display for errors.
  4. Check whether the thermostat is calling for heat: some show a symbol or light when heating.
  5. Note when it trips: immediately, after a while, or only after mopping the floor.

Do not open the thermostat or test cables yourself; the connections are at mains voltage.

Thermostat and Sensor Faults

Thermostats can fail from age or a power surge. The floor sensor is a small probe embedded in the floor; if it fails, many thermostats stop heating to protect the floor. Some thermostats can run in air-sensor mode as a temporary workaround. A failed sensor can sometimes be replaced if it was installed in a conduit; if it was embedded directly in adhesive, the thermostat may need to run without it.

Finding a Cable Break

If the controls are fine but the floor does not heat, the heating cable may be broken. Electricians test the resistance of the heating element and compare it with the manufacturer's figure. Very high or infinite resistance shows a break. Insulation resistance testing shows leakage to earth.

To find where the break is, specialist methods are used:

  • Thermal imaging with the heating running (if part works) shows cold sections.
  • Time domain reflectometry (TDR) sends a pulse down the cable and measures the distance to the fault.
  • Tracer equipment can follow the cable route under tiles.

These pinpoint the fault so only one or two tiles need lifting.

When a Mat Can Be Repaired

If the break is in one place and can be reached, the cable can usually be repaired with a manufacturer-approved repair kit, the joint insulated and the tile replaced. Repair is less likely to be practical if:

  • The cable has been damaged in several places.
  • The floor covering cannot be lifted without major damage.
  • The heating cable is an old or unidentified type.

Why Underfloor Heating Gets Damaged

  • Cables cut or nicked during installation, especially with tile cutters or trowels.
  • Screws or fixings driven into the floor later.
  • Heat build-up under rugs or furniture on older systems.
  • Water getting into connections in wet rooms.
  • No continuity or insulation testing before tiles were laid.

A good installer tests the mat before, during and after tiling and records the readings.

Underfloor Heating in Bathrooms

In a bathroom, the heating circuit needs 30 mA RCD protection and suitable equipment for the zone. Thermostats should be outside the zones close to the bath or shower. See bathroom extractor fan wiring and zones.

Frequently Asked Questions

Why does my underfloor heating trip the RCD?

Usually because the heating cable is damaged and leaking to earth, or water has reached a connection.

Can underfloor heating be repaired without lifting the floor?

Often, yes. The fault is located precisely and only one or two tiles are lifted.

How long does underfloor heating last?

The cable itself can last for decades if undamaged. Thermostats may need replacing sooner.

Is it worth repairing?

Usually, if the fault can be found and the floor finish can be patched.

Underfloor Heating Not Working?

We test and repair electric underfloor heating in Bath homes. See shower and heating repairs.

Related Electrical Guides

Fast Call-Out

Get an Emergency Electrician
Out in Bath

Call 07893 943507 and tell us what has happened: what has tripped or stopped working, whether you can smell burning, and whether water is involved. An electrician from Emergency Electrician Bath comes to your Bath property, makes it safe, finds the fault and agrees the price with you before any repair starts.