Electric showers draw more current than any other appliance in most homes, often 40 amps or more for ten minutes at a time. That makes them a common source of trips, scorched switches and cold water. This guide explains why showers trip the RCD, why they go cold or lukewarm, what the pull-cord switch and the cable have to do with it, and when it is worth repairing rather than replacing.
How an Electric Shower Is Wired
An electric shower has its own circuit from the consumer unit, protected by a circuit breaker and a 30 mA RCD. The cable runs to a double-pole isolating switch, usually a pull-cord switch on the bathroom ceiling, and from there to the shower unit. Inside the shower, the supply connects to a terminal block, then to the heating element and controls.
Shower Ratings and Cables
| Shower rating | Approximate current | Typical cable size |
|---|---|---|
| 7.5 kW | 31 A | 6 mm² |
| 8.5 kW | 35 A | 6 to 10 mm² |
| 9.5 kW | 40 A | 10 mm² |
| 10.5 kW | 44 A | 10 mm² |
The right cable depends on length, how it is installed and the protective device. Fitting a more powerful shower to an old cable is a common cause of overheating.
Why Showers Trip the RCD
- Failed heating element leaking current to earth, especially after limescale build-up.
- Water inside the unit from a cracked case, failed seal or damaged pressure relief device.
- Damaged cable behind tiles or in the ceiling void.
- Water in the pull-cord switch from condensation or a leak above.
- Loose connections at the terminal block.
Why Showers Trip the Breaker
If the circuit breaker rather than the RCD trips, the shower may be drawing more current than the circuit is designed for, or there may be a short circuit. This often happens when a more powerful shower has been fitted without upgrading the cable or breaker.
Why Showers Run Cold
- Failed element: one side of a twin element may fail, so the shower runs lukewarm.
- Thermal cut-out tripped: a safety device switches off the element if the shower overheats, often due to limescale or low water flow.
- Low water pressure: some showers reduce power or shut off when pressure is too low.
- Faulty pressure switch or flow switch.
- Loose connection reducing the power reaching the element.
The Pull-Cord Switch
The pull-cord isolating switch carries the full shower current. If its terminals are loose or the switch is undersized, it can overheat. Signs include a browned or scorched switch, a burning smell, or the cord feeling warm. A scorched isolator should be replaced immediately and the cable ends checked.
Burning Smell From the Shower
A burning smell usually means a connection at the terminal block, the isolator or the cable is overheating. Switch off at the isolator and the consumer unit, and do not use the shower until it has been checked. See burning smell from a socket or switch.
What You Can Check
- Note whether the RCD or the shower breaker tripped.
- Check whether the shower runs cold all the time, or only after a few minutes.
- Clean the shower head to improve flow.
- Check the pull-cord switch for discolouration from outside.
Do not open the shower unit. It contains mains connections and water.
Repair or Replace
| Situation | Usual advice |
|---|---|
| Shower under 5 years old, single fault | Repair: element, switch or terminal block |
| Shower over 10 years old, element failed | Replace may be better value |
| Scorched terminal block | Replace terminal block and check cable; often replace unit |
| Cable undersized for current shower | Upgrade cable or fit a lower-rated shower |
| Unit cracked or leaking | Replace |
Limescale in Bath
Bath's water is hard. Limescale builds up in shower heads and elements, reducing flow and causing overheating. Descaling the shower head regularly helps.
Frequently Asked Questions
Why does my shower trip the electrics?
Usually a failing element, water in the unit or a damaged cable.
Why does my shower go cold after a few minutes?
Often the thermal cut-out is tripping due to limescale or low flow.
Can I fit a more powerful shower?
Only if the cable and protection are suitable. Get it checked first.
Should a plumber or an electrician fix it?
An electrician for the circuit and connections; a plumber for water supply issues.